{"product_id":"cbi-samite-15a-3ka-1p-circuit-breaker","title":"CBI SAMITE 15A 3KA 1P CIRCUIT BREAKER","description":"\u003cp data-start=\"2832\" data-end=\"3199\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2836\" data-end=\"2884\"\u003eCBI 15 A 1P 3 kA Samite Mini Circuit Breaker\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, reliable circuit protection device — designed for safe, everyday electrical circuits in homes and small-scale commercial installations. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3039\" data-end=\"3068\"\u003esingle-pole configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for lighting circuits, small socket outlets, and other low- load applications needing dependable over-current protection.\u003c\/p\u003e\n\u003cp data-start=\"3201\" data-end=\"3632\"\u003eWith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3208\" data-end=\"3230\"\u003e15 A rated current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3235\" data-end=\"3261\"\u003e3 kA breaking capacity\u003c\/strong\u003e, this breaker effectively protects wiring and connected devices from overloads and short-circuit faults, reducing the risk of damage or fire. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3408\" data-end=\"3458\"\u003ehydraulic-magnetic C-curve trip characteristic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures responsive protection while tolerating normal surges or startup currents (for example from appliances or lighting loads), minimizing nuisance trips under normal use.\u003c\/p\u003e\n\u003cul data-start=\"461\" data-end=\"2777\"\u003e\n\u003cli data-start=\"518\" data-end=\"628\"\u003e\n\u003cp data-start=\"520\" data-end=\"628\"\u003e\u003cstrong data-start=\"520\" data-end=\"539\"\u003eModel \/ Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQA-1(13) Mini-Rail \/ Samite-mount 1-pole breaker\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"629\" data-end=\"730\"\u003e\n\u003cp data-start=\"631\" data-end=\"730\"\u003e\u003cstrong data-start=\"631\" data-end=\"640\"\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature Circuit Breaker (MCB), Single-Pole (1P)\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"731\" data-end=\"902\"\u003e\n\u003cp data-start=\"733\" data-end=\"902\"\u003e\u003cstrong data-start=\"733\" data-end=\"756\"\u003eRated Current (In):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 Amps — suitable for low- to moderate-load circuits (lighting, small socket circuits, small appliances)\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"1059\"\u003e\n\u003cp data-start=\"905\" data-end=\"1059\"\u003e\u003cstrong data-start=\"905\" data-end=\"939\"\u003eBreaking Capacity (Icu \/ Ics):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 kA — safely interrupts overloads or short-circuit fault currents up to 3000 A\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1060\" data-end=\"1237\"\u003e\n\u003cp data-start=\"1062\" data-end=\"1237\"\u003e\u003cstrong data-start=\"1062\" data-end=\"1081\"\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e240 V AC (single-phase domestic \/ commercial supply) — standard for residential and light-commercial installations.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1238\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1477\"\u003e\u003cstrong data-start=\"1240\" data-end=\"1280\"\u003eTripping Mechanism \/ Characteristic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHydraulic-magnetic with “C-curve” (standard) — provides overload and short-circuit protection while tolerating normal inrush\/start-up currents from devices.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1688\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1507\"\u003eMounting \/ Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSamite \/ Mini-rail — 13 mm module width; ultra-compact, designed to fit in standard Samite \/ mini-rail distribution boards \/ consumer units.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1689\" data-end=\"1885\"\u003e\n\u003cp data-start=\"1691\" data-end=\"1885\"\u003e\u003cstrong data-start=\"1691\" data-end=\"1717\"\u003ePoles \/ Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-pole (1P) — protects one live conductor; suitable for single-phase circuits (lighting, sockets, small power circuits).\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1886\" data-end=\"2088\"\u003e\n\u003cp data-start=\"1888\" data-end=\"2088\"\u003e\u003cstrong data-start=\"1888\" data-end=\"1912\"\u003eProtection Provided:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOverload protection \u0026amp; short-circuit protection — safeguards wiring and connected devices from electrical faults, surges or overloads.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2089\" data-end=\"2304\"\u003e\n\u003cp data-start=\"2091\" data-end=\"2304\"\u003e\u003cstrong data-start=\"2091\" data-end=\"2123\"\u003ePhysical Dimensions \/ Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact plastic housing, 13 mm width module — minimal space consumption; typical Mini-Rail mounting height\/width as per CBI specification.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2305\" data-end=\"2498\"\u003e\n\u003cp data-start=\"2307\" data-end=\"2498\"\u003e\u003cstrong data-start=\"2307\" data-end=\"2334\"\u003eStandards \/ Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with relevant standards applicable to low-voltage MCBs (IEC\/SANS \/ manufacturer spec for Samite-rail breakers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2499\" data-end=\"2777\"\u003e\n\u003cp data-start=\"2501\" data-end=\"2777\"\u003e\u003cstrong data-start=\"2501\" data-end=\"2526\"\u003eTypical Applications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDomestic homes, apartments, small offices — lighting circuits, socket circuits, small-appliance power circuits, sub-circuits requiring 15 A protection; ideal for retrofit or new install in Samite-rail boards.\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CBI","offers":[{"title":"Default Title","offer_id":48115327140069,"sku":"CBI\/15A","price":205.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0742\/7191\/6261\/files\/sys-master_root_hb5_h03_15058420563998_large_null.jpg?v=1764766296","url":"https:\/\/cajeeslighting.co.za\/products\/cbi-samite-15a-3ka-1p-circuit-breaker","provider":"Cajees Lighting and Electrical","version":"1.0","type":"link"}