{"product_id":"cbi-samite-20a-3ka-1p-circuit-breaker","title":"CBI SAMITE 20A 3KA 1P CIRCUIT BREAKER","description":"\u003cp data-start=\"2157\" data-end=\"2559\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2161\" data-end=\"2209\"\u003eCBI 20 A 1P 3 kA Samite Mini Circuit Breaker\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-quality protection device designed to safeguard single-phase circuits in homes, offices, and light-commercial settings. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2353\" data-end=\"2382\"\u003esingle-pole configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the live conductor is protected, providing dependable overload and short-circuit protection for lighting circuits, socket outlets, and small-appliance connections.\u003c\/p\u003e\n\u003cp data-start=\"2561\" data-end=\"3017\"\u003eWith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2568\" data-end=\"2591\"\u003e20 A current rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2596\" data-end=\"2622\"\u003e3 kA breaking capacity\u003c\/strong\u003e, this breaker is engineered to safely interrupt hazardous fault currents — protecting wiring, appliances, and devices from damage or fire risk. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2771\" data-end=\"2819\"\u003eC-curve thermal-magnetic trip characteristic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a balanced response: sensitive enough to respond to overloads, yet tolerant of typical startup or inrush currents from appliances or equipment — preventing nuisance trips under normal usage.\u003c\/p\u003e\n\u003cul data-start=\"238\" data-end=\"2102\"\u003e\n\u003cli data-start=\"295\" data-end=\"396\"\u003e\n\u003cp data-start=\"297\" data-end=\"396\"\u003e\u003cstrong data-start=\"297\" data-end=\"306\"\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature Circuit Breaker (MCB), Single-Pole (1P)\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"397\" data-end=\"566\"\u003e\n\u003cp data-start=\"399\" data-end=\"566\"\u003e\u003cstrong data-start=\"399\" data-end=\"422\"\u003eRated Current (In):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 Amps — suitable for standard single-phase circuits like lighting, sockets, small-appliance circuits.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"567\" data-end=\"737\"\u003e\n\u003cp data-start=\"569\" data-end=\"737\"\u003e\u003cstrong data-start=\"569\" data-end=\"603\"\u003eBreaking Capacity (Icu \/ Ics):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 kA — capable of safely interrupting fault (short-circuit \/ overload) currents up to 3000 A.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"738\" data-end=\"857\"\u003e\n\u003cp data-start=\"740\" data-end=\"857\"\u003e\u003cstrong data-start=\"740\" data-end=\"759\"\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~220-240 V AC (single-phase domestic \/ commercial supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"858\" data-end=\"1073\"\u003e\n\u003cp data-start=\"860\" data-end=\"1073\"\u003e\u003cstrong data-start=\"860\" data-end=\"887\"\u003eMounting \/ Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSamite \/ Mini-rail mount — ultra-compact (13 mm wide module) suitable for standard Samite-rail or mini-rail distribution boards \/ consumer units.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1304\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1304\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1108\"\u003eTrip Curve \/ Characteristic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eC-curve (often labelled “C3” or similar) — thermal-magnetic trip to handle overload and short-circuit protection with tolerance for normal inrush currents.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1305\" data-end=\"1502\"\u003e\n\u003cp data-start=\"1307\" data-end=\"1502\"\u003e\u003cstrong data-start=\"1307\" data-end=\"1330\"\u003ePole Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-pole (1P) — protects a single live conductor; appropriate for single-phase circuits (lighting, socket outlets, small loads).\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1503\" data-end=\"1692\"\u003e\n\u003cp data-start=\"1505\" data-end=\"1692\"\u003e\u003cstrong data-start=\"1505\" data-end=\"1529\"\u003eProtection Provided:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOverload protection \u0026amp; short-circuit protection — safeguards wiring and connected devices from electrical faults or surges.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1865\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1865\"\u003e\u003cstrong data-start=\"1695\" data-end=\"1722\"\u003eStandards \/ Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with applicable standards (VC8036 \/ SANS 556-1 \/ IEC 60947-2) for Samite \/ mini-rail MCBs.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1866\" data-end=\"2102\"\u003e\n\u003cp data-start=\"1868\" data-end=\"2102\"\u003e\u003cstrong data-start=\"1868\" data-end=\"1893\"\u003eTypical Applications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDomestic and light-commercial installations — lighting circuits, socket points, small appliance circuits, general-purpose single-phase wiring requiring 20 A protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CBI","offers":[{"title":"Default Title","offer_id":48115323338981,"sku":"CBI\/20A","price":205.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0742\/7191\/6261\/files\/sys-master_root_h1d_h74_15058421743646_large_null.jpg?v=1764766148","url":"https:\/\/cajeeslighting.co.za\/products\/cbi-samite-20a-3ka-1p-circuit-breaker","provider":"Cajees Lighting and Electrical","version":"1.0","type":"link"}