{"product_id":"cbi-samite-63a-3ka-earth-leakage-no-overload","title":"CBI SAMITE 63A 2P 3KA EARTH LEAKAGE","description":"\u003cp data-end=\"2976\" data-start=\"2579\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"2628\" data-start=\"2583\"\u003eCBI (QA17A63) 63A 3kA Samite Earth-Leakage Device\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity, high-sensitivity residual-current breaker designed to protect electrical installations from earth-fault leakage, reducing risk of electric shock or fire. With its\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"2835\" data-start=\"2812\"\u003e63 A current rating\u003c\/strong\u003e, it’s suitable for main supply lines, sub-mains, or high-load circuits, making it ideal for both domestic and light-commercial environments.\u003c\/p\u003e\n\u003cp data-end=\"3390\" data-start=\"2978\"\u003eFeaturing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"3019\" data-start=\"2990\"\u003e30mA leakage sensitivity\u003c\/strong\u003e, this unit quickly detects even small leakage currents — such as those caused by insulation degradation, moisture ingress, or stray fault currents — and trips the circuit to prevent danger. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"3240\" data-start=\"3214\"\u003e3 kA breaking capacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that in the event of a fault or short circuit, the device interrupts the current safely, protecting wiring, appliances, and the installation.\u003c\/p\u003e\n\u003cul data-end=\"2524\" data-start=\"301\"\u003e\n\u003cli data-end=\"735\" data-start=\"581\"\u003e\n\u003cp data-end=\"735\" data-start=\"583\"\u003e\u003cstrong data-end=\"606\" data-start=\"583\"\u003eRated Current (In):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e63 Amps — suitable for heavy-duty single-phase supply circuits, sub-mains or main feeds.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"871\" data-start=\"736\"\u003e\n\u003cp data-end=\"871\" data-start=\"738\"\u003e\u003cstrong data-end=\"768\" data-start=\"738\"\u003eLeakage Sensitivity (IΔn):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 mA — trips when residual\/earth-fault current exceeds 30 mA.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1042\" data-start=\"872\"\u003e\n\u003cp data-end=\"1042\" data-start=\"874\"\u003e\u003cstrong data-end=\"924\" data-start=\"874\"\u003eBreaking \/ Fault-Current Capacity (Icu \/ Ics):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 kA — able to safely interrupt fault or short-circuit currents up to 3000 A.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1296\" data-start=\"1043\"\u003e\n\u003cp data-end=\"1296\" data-start=\"1045\"\u003e\u003cstrong data-end=\"1064\" data-start=\"1045\"\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~220–240 V AC (single-phase) for 1P+N versions, or 415 V (3P+N) for three-phase variants (depending on model) — suitable for typical residential, commercial or light-industrial installations.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1480\" data-start=\"1297\"\u003e\n\u003cp data-end=\"1480\" data-start=\"1299\"\u003e\u003cstrong data-end=\"1325\" data-start=\"1299\"\u003ePoles \/ Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Pole + Neutral (1P+N) for single-phase; or 3 Pole + Neutral (3P+N) for three-phase versions, depending on model.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1704\" data-start=\"1481\"\u003e\n\u003cp data-end=\"1704\" data-start=\"1483\"\u003e\u003cstrong data-end=\"1510\" data-start=\"1483\"\u003eMounting \/ Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSamite \/ Mini-rail mount (compact width module, typically 26 mm) — designed for standard Samite-rail or mini-rail distribution boards and consumer units.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1917\" data-start=\"1705\"\u003e\n\u003cp data-end=\"1917\" data-start=\"1707\"\u003e\u003cstrong data-end=\"1726\" data-start=\"1707\"\u003eTrip Mechanism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHydraulic-magnetic \/ residual-current mechanism — detects imbalance between live and neutral (earth \/ leakage current) and trips within required time.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2168\" data-start=\"1918\"\u003e\n\u003cp data-end=\"2168\" data-start=\"1920\"\u003e\u003cstrong data-end=\"1954\" data-start=\"1920\"\u003eStandards \/ Safety Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with relevant safety standards for earth-leakage devices (e.g., standard leakage sensitivity 30 mA, meets VC 8035 \/ IEC\/EN 60947-2 requirements for RCDs \/ ELBs).\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2524\" data-start=\"2169\"\u003e\n\u003cp data-end=\"2524\" data-start=\"2171\"\u003e\u003cstrong data-end=\"2196\" data-start=\"2171\"\u003eTypical Applications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eResidential or commercial circuit protection requiring earth-leakage \/ residual-current protection — e.g. main incoming supply, sub-mains, heavy-load socket banks, geyser circuits, workshops, or any circuit where protection from earth-fault\/leakage and electric shock risk is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CBI","offers":[{"title":"Default Title","offer_id":48115345817829,"sku":"CBI17C\/63A","price":1115.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0742\/7191\/6261\/files\/HEI-0557.webp?v=1764767277","url":"https:\/\/cajeeslighting.co.za\/products\/cbi-samite-63a-3ka-earth-leakage-no-overload","provider":"Cajees Lighting and Electrical","version":"1.0","type":"link"}